batgrbproduct analysis for trigger=968212

batgrbproduct Analysis for Trigger=968212

Analysis Summary

Notes:

======================================================================
                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.47
    Process Start Time (local time): Sun May  3 22:26:18 EDT 2020
             Host Name: bat1
   Current Working Dir: /local/data/bat1/prebascript/trigger968212/batgroup_hand_proc
======================================================================

  Trigger: 00968212      Segment: 000

  BAT Trigger Time: 609705204.824   [s; MET]
      Trigger Stop: 609705204.84   [s; MET]
               UTC: 2020-04-27T18:32:59.978920    [includes UTCF correction] 
       Where From?: (*SHORT BURST*) TDRSS scaled map message

  BAT 
    RA: 293.727220878258   Dec: 21.8919792132577  [deg; J2000]

     Catalogged Source?: YES
     Point Source?:      YES
     GRB Indicated?:     NO    [ by BAT flight software ]
     Image S/N Ratio:    19.17
     Image Trigger?:     NO
     Rate S/N Ratio:     255.998046867549  [ if not an image trigger ]
     Image S/N Ratio:    19.17

  Flight Position:   [ source = BAT ]
    RA: 293.727220878258   Dec: 21.8919792132577  [deg; J2000]


  Partial Coding Fraction:     [ including projection effects ]

 
  Angular difference between Flight and Ground position is 0.000000 arcmin
 
  Partial Coding Fraction:     [ including projection effects ]

  Duration
     T90: 619.771999955177 +/- 24.8480321262417
        Measured from: 226.05999994278
                   to: 845.831999897957     [s; relative to TRIGTIME]
     T50: 606.283999919891 +/- 785.433080555095
        Measured from: 226.100000023842
                   to: 832.383999943733     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: 225.842000007629     
                   to: 226.842000007629     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: 226.052000045776     
                   to: 845.84399998188     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     3.912952   3.955664   1.057667   0.750262
           0.578533   0.585017   0.496172   0.440603 [error]
 Peak      1.204751   1.398308   0.234006  -0.001570
           0.103956   0.103872   0.056382   0.026204 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================
 
=== Fluence/Peak Flux Summary ===
 
              Model    Band1    Band2    Band3    Band4    Band5    Total      
                       15-25    25-50   50-100  100-350   15-150   15-350   keV
Fluence   Power-law -------- -------- -------- -------- -------- --------   erg/cm2
              Error -------- -------- -------- -------- -------- --------   erg/cm2
Peak flux Power-law -------- -------- -------- -------- -------- --------   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
Fluence   Cutoff-PL -------- -------- -------- -------- -------- --------   erg/cm2
              Error -------- -------- -------- -------- -------- --------   erg/cm2
Peak flux Cutoff-PL -------- -------- -------- -------- -------- --------   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
Fluence        Band -------- -------- -------- -------- -------- --------   erg/cm2
              Error -------- -------- -------- -------- -------- --------   erg/cm2
Peak flux      Band -------- -------- -------- -------- -------- --------   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
=== Time-averaged spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
 
=== 1-s peak spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
Model      : spectral model: simple power-law (PL) and cutoff power-law (CPL)
Ph_index   : photon index: E^-{Ph_index} (minus sign is not included in the index)
Ph_90err   : 90% error of the photon index
Epeak      : Epeak in keV
Epeak_90err: 90% error of Epeak
Norm       : normalization at 50 keV in PL model and at 1 keV in CPL model
Nomr_90err : 90% error of the normalization
chi2       : Chi-Squared
dof        : degree of freedom
 
=== T90/T50 calculation in the 50-300 keV band (BATSE band) using 64 ms lc ===
 
T90 in the 50-300 keV band: 0.000000 sec.
T50 in the 50-300 keV band: 0.000000 sec.
 
=== Table of the duration information ==
 
        Value   tstart    tstop
T100  619.792  226.052  845.844
T90   619.772  226.060  845.832
T50   606.284  226.100  832.384
Peak    1.000  225.842  226.842

Image

Pre-slew 15-350 keV image (Event data; bkg subtracted)

 
Foreground time interval of the image:
Background time interval of the image:

Lightcurves

Notes:

1 s binning

From T0-310 s to T0+310 s
From T100_start - 20 s to T100_end + 30 s
Full time interval

64 ms binning

Full time interval
From T100_start to T100_end
From T0-5 sec to T0+5 sec

16 ms binning

From T100_start-5 s to T100_start+5 s

8 ms binning

From T100_start-3 s to T100_start+3 s

2 ms binning

From T100_start-1 s to T100_start+1 s

SN=5 or 10 sec. binning (whichever binning is satisfied first)

SN=5 or 10 sec. binning (T < 200 sec)

Spectra

Notes:

Time averaged spectrum fit using the pre-slew DRM

Power-law model
Multiple GTIs in the spectrum
tstart tstop
226.052000 376.256000
743.176000 845.844000
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Multiple GTIs in the spectrum
tstart tstop
226.052000 376.256000
743.176000 845.844000
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Multiple GTIs in the spectrum
tstart tstop
226.052000 376.256000
743.176000 845.844000
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            

Peak spectrum fit

Power-law model
Time interval is from  225.842 sec. to  226.842 sec.
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Time interval is from  225.842 sec. to  226.842 sec.
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Time interval is from  225.842 sec. to  226.842 sec.
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Plot creation:
Sun May  3 22:31:43 EDT 2020