batgrbproduct analysis for trigger=1192740

batgrbproduct Analysis for Trigger=1192740

Analysis Summary

Notes:

======================================================================
                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time (local time): Wed Sep 27 13:00:49 EDT 2023
             Host Name: batproc1
   Current Working Dir: /local/data/bat1/prebascript/trigger1192740/GCN5_download_cron
======================================================================

  Trigger: 01192740      Segment: 000

  BAT Trigger Time: 717460288   [s; MET]
      Trigger Stop: 717460352   [s; MET]
               UTC: 2023-09-26T22:30:55.919120    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 245.078530258714   Dec: -16.2340223227555  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    8.57
     Image Trigger?:     YES
     Rate S/N Ratio:     0  [ if not an image trigger ]
     Image S/N Ratio:    8.57

  Flight Position:   [ source = BAT ]
    RA: 245.078530258714   Dec: -16.2340223227555  [deg; J2000]


  Partial Coding Fraction:     [ including projection effects ]

 
  Angular difference between Flight and Ground position is 0.000000 arcmin
 
  Partial Coding Fraction:     [ including projection effects ]

  Duration
     T90: 19.2039999961853 +/- 12.0812236867474
        Measured from: 92.3440001010895
                   to: 111.548000097275     [s; relative to TRIGTIME]
     T50: 19.2039999961853 +/- 12.8623756786078
        Measured from: 92.3440001010895
                   to: 111.548000097275     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: 97.8799999952316     
                   to: 98.8799999952316     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: 92.3439999818802     
                   to: 111.547999978065     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     1.098878   0.083128   0.041339   0.007373
           0.063447   0.055344   0.045442   0.039236 [error]
 Peak      0.077206   0.012565   0.024861   0.020804
           0.015095   0.014080   0.012129   0.009585 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================
 
=== Fluence/Peak Flux Summary ===
 
              Model    Band1    Band2    Band3    Band4    Band5    Total      
                       15-25    25-50   50-100  100-350   15-150   15-350   keV
Fluence   Power-law -------- -------- -------- -------- -------- --------   erg/cm2
              Error -------- -------- -------- -------- -------- --------   erg/cm2
Peak flux Power-law -------- -------- -------- -------- -------- --------   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
Fluence   Cutoff-PL -------- -------- -------- -------- -------- --------   erg/cm2
              Error -------- -------- -------- -------- -------- --------   erg/cm2
Peak flux Cutoff-PL -------- -------- -------- -------- -------- --------   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
Fluence        Band -------- -------- -------- -------- -------- --------   erg/cm2
              Error -------- -------- -------- -------- -------- --------   erg/cm2
Peak flux      Band -------- -------- -------- -------- -------- --------   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
=== Time-averaged spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
 
=== 1-s peak spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
Model      : spectral model: simple power-law (PL) and cutoff power-law (CPL)
Ph_index   : photon index: E^-{Ph_index} (minus sign is not included in the index)
Ph_90err   : 90% error of the photon index
Epeak      : Epeak in keV
Epeak_90err: 90% error of Epeak
Norm       : normalization at 50 keV in PL model and at 1 keV in CPL model
Nomr_90err : 90% error of the normalization
chi2       : Chi-Squared
dof        : degree of freedom
 
=== T90/T50 calculation in the 50-300 keV band (BATSE band) using 64 ms lc ===
 
T90 in the 50-300 keV band: 0.000000 sec.
T50 in the 50-300 keV band: 0.000000 sec.
 
=== Table of the duration information ==
 
        Value   tstart    tstop
T100   19.204   92.344  111.548
T90    19.204   92.344  111.548
T50    19.204   92.344  111.548
Peak    1.000   97.880   98.880

Image

Pre-slew 15-350 keV image (Event data; bkg subtracted)

 
Foreground time interval of the image:
Background time interval of the image:

Lightcurves

Notes:

1 s binning

From T0-310 s to T0+310 s
From T100_start - 20 s to T100_end + 30 s
Full time interval

64 ms binning

Full time interval
From T100_start to T100_end
From T0-5 sec to T0+5 sec

16 ms binning

From T100_start-5 s to T100_start+5 s

8 ms binning

From T100_start-3 s to T100_start+3 s

2 ms binning

From T100_start-1 s to T100_start+1 s

SN=5 or 10 sec. binning (whichever binning is satisfied first)

SN=5 or 10 sec. binning (T < 200 sec)

Spectra

Notes:

Time averaged spectrum fit using the pre-slew DRM

Power-law model
Time interval is from   92.344 sec. to  111.548 sec.
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Time interval is from   92.344 sec. to  111.548 sec.
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Time interval is from   92.344 sec. to  111.548 sec.
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            

Peak spectrum fit

Power-law model
Time interval is from   97.880 sec. to   98.880 sec.
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Time interval is from   97.880 sec. to   98.880 sec.
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Time interval is from   97.880 sec. to   98.880 sec.
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Plot creation:
Wed Sep 27 13:02:25 EDT 2023