batgrbproduct analysis for trigger=1144538

batgrbproduct Analysis for Trigger=1144538

Analysis Summary

Notes:

======================================================================
                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time (local time): Fri Dec 16 13:37:08 EST 2022
             Host Name: batproc1
   Current Working Dir: /local/data/bat1/prebascript/trigger1144538/GCN5_download_cron
======================================================================

  Trigger: 01144538      Segment: 000

  BAT Trigger Time: 692768154.752   [s; MET]
      Trigger Stop: 692768155.776   [s; MET]
               UTC: 2022-12-15T03:35:24.356200    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 54.7890869015672   Dec: -27.4328377625161  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    6.55
     Image Trigger?:     NO
     Rate S/N Ratio:     6.78232998312527  [ if not an image trigger ]
     Image S/N Ratio:    6.55

  Flight Position:   [ source = BAT ]
    RA: 54.7890869015672   Dec: -27.4328377625161  [deg; J2000]

  Ground Position:   [ source = BAT pre-slew burst ]
    RA: 54.7181617299325   Dec: -27.4043954441258  [deg; J2000]  
        { 03h 38m 52.4s , -27d 24' 15.8" }
         +/- 4.95449557533407 [arcmin] (estimated 90% radius based on SNR)
         +/- 3.59627905025665 [arcmin] (formal 1-sigma fit error)
    SNR: 3.0921605146034
 
  Angular difference between Flight and Ground position is 4.145065 arcmin
 
  Partial Coding Fraction: 1.03125    [ including projection effects ]

  Duration
     T90: 0.587999939918518 +/- 0.0576887720036286
        Measured from: 195.856000185013
                   to: 196.444000124931     [s; relative to TRIGTIME]
     T50: 0.347999930381775 +/- 0.123223409357101
        Measured from: 195.988000154495
                   to: 196.336000084877     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: 195.740000009537     
                   to: 196.740000009537     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: 195.84399998188     
                   to: 196.488000035286     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total    -0.123336  -0.101035  -0.141009  -0.288176
           0.036986   0.043562   0.040705   0.057128 [error]
 Peak     -0.141724  -0.090753  -0.147477  -0.283056
           0.045957   0.053359   0.049246   0.069922 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================
 
=== Fluence/Peak Flux Summary ===
 
              Model    Band1    Band2    Band3    Band4    Band5    Total      
                       15-25    25-50   50-100  100-350   15-150   15-350   keV
Fluence   Power-law 4.44e-10 2.74e-09 1.48e-08 3.62e-07 4.83e-08 3.79e-07   erg/cm2
              Error 9.87e-10 3.35e-09 1.13e-08 5.40e-07 2.16e-08 5.45e-07   erg/cm2
Peak flux Power-law 1.34e-02 4.38e-02 1.18e-01 9.37e-01 3.23e-01 1.11e+00   ph/cm2/s
              Error 3.05e-02 5.53e-02 9.14e-02 1.26e+00 2.47e-01 1.06e+00   ph/cm2/s
 
Fluence   Cutoff-PL 6.88e-12 7.23e-10 1.85e-08 4.86e-08 4.99e-08 6.88e-08   erg/cm2
              Error 6.65e-10 2.67e-09 1.13e-08 3.44e-07 2.32e-08 3.91e-07   erg/cm2
Peak flux Cutoff-PL 1.76e-04 1.03e-02 1.42e-01 2.14e-01 3.06e-01 3.64e-01   ph/cm2/s
              Error 1.66e-02 4.36e-02 9.12e-02 -------- 1.39e-01 9.17e-01   ph/cm2/s
 
Fluence        Band -------- -------- -------- -------- -------- --------   erg/cm2
              Error -------- -------- -------- -------- -------- --------   erg/cm2
Peak flux      Band -------- -------- -------- -------- -------- --------   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
=== Time-averaged spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
 
=== 1-s peak spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
Model      : spectral model: simple power-law (PL) and cutoff power-law (CPL)
Ph_index   : photon index: E^-{Ph_index} (minus sign is not included in the index)
Ph_90err   : 90% error of the photon index
Epeak      : Epeak in keV
Epeak_90err: 90% error of Epeak
Norm       : normalization at 50 keV in PL model and at 1 keV in CPL model
Nomr_90err : 90% error of the normalization
chi2       : Chi-Squared
dof        : degree of freedom
 
=== T90/T50 calculation in the 50-300 keV band (BATSE band) using 64 ms lc ===
 
T90 in the 50-300 keV band: 0.000000 sec.
T50 in the 50-300 keV band: 0.000000 sec.
 
=== Table of the duration information ==
 
        Value   tstart    tstop
T100    0.644  195.844  196.488
T90     0.588  195.856  196.444
T50     0.348  195.988  196.336
Peak    1.000  195.740  196.740

Image

Pre-slew 15-350 keV image (Event data; bkg subtracted)

#   RAcent  DECcent POSerr  Theta    Phi     Peak Cts     SNR  Name
   54.7182 -27.4044 0.0621    9.2 -147.6       0.0542     3.1  TRIG_01144538       
------------------------------------------
 
Foreground time interval of the image:
  0.000   1.024 (delta_t =   1.024 [sec])
Background time interval of the image:
-239.752 -10.752 (delta_t = 229.000 [sec])

Lightcurves

Notes:

1 s binning

From T0-310 s to T0+310 s
From T100_start - 20 s to T100_end + 30 s
Full time interval

64 ms binning

Full time interval
From T100_start to T100_end
From T0-5 sec to T0+5 sec

16 ms binning

From T100_start-5 s to T100_start+5 s

8 ms binning

From T100_start-3 s to T100_start+3 s

2 ms binning

From T100_start-1 s to T100_start+1 s

SN=5 or 10 sec. binning (whichever binning is satisfied first)

SN=5 or 10 sec. binning (T < 200 sec)

Spectra

Notes:

Time averaged spectrum fit using the pre-slew DRM

Power-law model
Time interval is from  195.844 sec. to  196.488 sec.
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Time interval is from  195.844 sec. to  196.488 sec.
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Time interval is from  195.844 sec. to  196.488 sec.
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            

Peak spectrum fit

Power-law model
Time interval is from  195.740 sec. to  196.740 sec.
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Time interval is from  195.740 sec. to  196.740 sec.
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Time interval is from  195.740 sec. to  196.740 sec.
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Plot creation:
Fri Dec 16 13:38:47 EST 2022