batgrbproduct analysis for trigger=1069242

batgrbproduct Analysis for Trigger=1069242

Analysis Summary

Notes:

======================================================================
                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time (local time): Thu Aug 19 15:52:34 EDT 2021
             Host Name: batproc1
   Current Working Dir: /local/data/bat1/prebascript/trigger1069242/GCN5_download_cron
======================================================================

  Trigger: 01069242      Segment: 000

  BAT Trigger Time: 650996248   [s; MET]
      Trigger Stop: 650996312   [s; MET]
               UTC: 2021-08-18T16:17:00.428980    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 299.818776326101   Dec: 35.2770795652221  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    12.49
     Image Trigger?:     YES
     Rate S/N Ratio:     0  [ if not an image trigger ]
     Image S/N Ratio:    12.49

  Flight Position:   [ source = BAT ]
    RA: 299.818776326101   Dec: 35.2770795652221  [deg; J2000]

  Ground Position:   [ source = BAT pre-slew burst ]
    RA: 299.778136414175   Dec: 35.2698552379913  [deg; J2000]  
        { 19h 59m 06.8s , +35d 16' 11.5" }
         +/- 1.63180315791741 [arcmin] (estimated 90% radius based on SNR)
         +/- 0.700815231910457 [arcmin] (formal 1-sigma fit error)
    SNR: 15.1114897550909
 
  Angular difference between Flight and Ground position is 2.037362 arcmin
 
  Partial Coding Fraction: 0.828125    [ including projection effects ]

  Duration
     T90: 395.647999882698 +/- 191.997385172258
        Measured from: 315.904000163078
                   to: 711.552000045776     [s; relative to TRIGTIME]
     T50: 221.927999973297 +/- 49.7244858909304
        Measured from: 412.340000152588
                   to: 634.268000125885     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: 606.552000045776     
                   to: 607.552000045776     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: 143.259999990463     
                   to: 795.544000029564     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     3.997515   3.947053   1.813850   0.381608
           0.155891   0.158598   0.138301   0.129502 [error]
 Peak      0.013451   0.011632   0.017942   0.014627
           0.006526   0.006556   0.005733   0.005413 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================
 
=== Fluence/Peak Flux Summary ===
 
              Model    Band1    Band2    Band3    Band4    Band5    Total      
                       15-25    25-50   50-100  100-350   15-150   15-350   keV
Fluence   Power-law 2.45e-07 2.87e-07 2.43e-07 3.49e-07 9.00e-07 1.12e-06   erg/cm2
              Error 3.08e-08 2.83e-08 4.62e-08 1.28e-07 1.05e-07 1.85e-07   erg/cm2
Peak flux Power-law 1.27e-01 8.30e-02 3.51e-02 2.03e-02 2.56e-01 2.66e-01   ph/cm2/s
              Error 1.64e-02 7.99e-03 6.45e-03 6.94e-03 2.38e-02 2.49e-02   ph/cm2/s
 
Fluence   Cutoff-PL 2.37e-07 3.07e-07 2.22e-07 1.06e-07 8.35e-07 8.73e-07   erg/cm2
              Error 3.32e-08 3.94e-08 6.21e-08 1.75e-07 1.30e-07 2.61e-07   erg/cm2
Peak flux Cutoff-PL 1.22e-01 8.86e-02 3.27e-02 7.69e-03 2.49e-01 2.51e-01   ph/cm2/s
              Error 1.79e-02 1.12e-02 8.33e-03 1.27e-02 2.52e-02 2.84e-02   ph/cm2/s
 
Fluence        Band 2.31e-07 3.13e-07 2.13e-07 2.17e-07 8.48e-07 9.82e-07   erg/cm2
              Error 3.42e-08 -------- -------- -------- -------- --------   erg/cm2
Peak flux      Band -------- -------- -------- -------- -------- --------   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
=== Time-averaged spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
The chi2 of BB fit is 93.26 which shows a significant improvement in the fit over a PL.
Check the BB fit.
 
=== 1-s peak spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
Model      : spectral model: simple power-law (PL) and cutoff power-law (CPL)
Ph_index   : photon index: E^-{Ph_index} (minus sign is not included in the index)
Ph_90err   : 90% error of the photon index
Epeak      : Epeak in keV
Epeak_90err: 90% error of Epeak
Norm       : normalization at 50 keV in PL model and at 1 keV in CPL model
Nomr_90err : 90% error of the normalization
chi2       : Chi-Squared
dof        : degree of freedom
 
=== T90/T50 calculation in the 50-300 keV band (BATSE band) using 64 ms lc ===
 
T90 in the 50-300 keV band: 0.000000 sec.
T50 in the 50-300 keV band: 0.000000 sec.
 
=== Table of the duration information ==
 
        Value   tstart    tstop
T100  652.284  143.260  795.544
T90   395.648  315.904  711.552
T50   221.928  412.340  634.268
Peak    1.000  606.552  607.552

Image

Pre-slew 15-350 keV image (Event data; bkg subtracted)

#   RAcent  DECcent POSerr  Theta    Phi     Peak Cts     SNR  Name
  299.7781 +35.2699 0.0127   25.0  163.7       2.0240    15.1  TRIG_01069242       
------------------------------------------
 
Foreground time interval of the image:
  0.000  28.950 (delta_t =  28.950 [sec])
 30.000  64.000 (delta_t =  34.000 [sec])
Background time interval of the image:

Lightcurves

Notes:

1 s binning

From T0-310 s to T0+310 s
From T100_start - 20 s to T100_end + 30 s
Full time interval

64 ms binning

Full time interval
From T100_start to T100_end
From T0-5 sec to T0+5 sec

16 ms binning

From T100_start-5 s to T100_start+5 s

8 ms binning

From T100_start-3 s to T100_start+3 s

2 ms binning

From T100_start-1 s to T100_start+1 s

SN=5 or 10 sec. binning (whichever binning is satisfied first)

SN=5 or 10 sec. binning (T < 200 sec)

Spectra

Notes:

Time averaged spectrum fit using the pre-slew DRM

Power-law model
Multiple GTIs in the spectrum
tstart tstop
143.260000 654.197400
661.000000 714.550000
781.000000 795.544000
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Multiple GTIs in the spectrum
tstart tstop
143.260000 654.197400
661.000000 714.550000
781.000000 795.544000
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Multiple GTIs in the spectrum
tstart tstop
143.260000 654.197400
661.000000 714.550000
781.000000 795.544000
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            

Peak spectrum fit

Power-law model
Time interval is from  606.552 sec. to  607.552 sec.
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Time interval is from  606.552 sec. to  607.552 sec.
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Time interval is from  606.552 sec. to  607.552 sec.
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Plot creation:
Thu Aug 19 15:55:47 EDT 2021