TITLE: GCN GRB OBSERVATION REPORT NUMBER: 348 SUBJECT: X-ray/GRB 1SAX J0835.9+5118, Optical Observation DATE: 99/05/29 06:58:57 GMT FROM: Holger Pedersen at Copenhagen U Obs H. Pedersen, J. Hjorth, B. L. Jensen (Copenhagen), H. Korhonen, and M. I. Andersen (NOT) report: We have conducted a second (cf. GCN 340) series of imaging using the 2.56-m Nordic Optical Telescope. The StanCam instrument was used, giving a field of 3' x 3', hence significantly smaller than the 3' radius error circle (GCN 333). Three 5-min R-band images were acquired on May 25.927 UT. The seeing was 0.9" FWHM. We find no evidence for variability between the two observing epochs. Specifically, the sn-like configuration mentioned in GCN 340 does not show any variability in support of its association with the high energy event. The sum image from the two runs can be inspected at http://www.astro.ku.dk/~holger/g/XRT990520/news.html The new images do not cover the position of the radio source discovered by Frail et al. (GCN 334). For the optical counterpart to this latter source (cf. GCN 335, 336, 338, 341, 345) we have deduced the brightness at the epoch of our first observing session, May 20.90 UT, finding R = 20.84 +- 0.05.