TITLE: GCN CIRCULAR NUMBER: 23754 SUBJECT: GRB 190114C: REM optical/NIR detection (CORRECTION) DATE: 19/01/18 10:30:16 GMT FROM: Paolo D'Avanzo at INAF-OAB P. D'Avanzo (INAF-OAB), on behalf of the REM team, report: We noticed a typo in our GCN Circular 23729 (D'Avanzo et al.), reporting about REM observations of GRB 190114C. In that GCN Circular we reported a H-band magnitude, while the filter used to measure the NIR afterglow magnitude was J. So, the magnitudes we measure in the REM images of GRB 190114C are: r = 18.6 +/- 0.2 J = 16.7 +/- 0.1 (AB; calibrated against the pan-STARRS and the 2MASS catalogues), at a mean time of about 4.3 hours after the GRB. We apologize for any confusion this may have caused.