TITLE: GCN CIRCULAR NUMBER: 25118 SUBJECT: LIGO/Virgo S190720a: Coverage and upper limits from MAXI/GSC observations DATE: 19/07/20 05:17:16 GMT FROM: Motoko Serino at RIKEN/MAXI N. Kawai, M. Sugizaki (Tokyo Tech), H. Negoro (Nihon U.), S. Sugita, M. Serino (AGU), M. Nakajima, W. Maruyama, M. Aoki, K. Kobayashi (Nihon U.), S. Nakahira, T. Mihara, T. Tamagawa, M. Matsuoka (RIKEN), T. Sakamoto, H. Nishida, A. Yoshida (AGU), Y. Tsuboi, W. Iwakiri, R. Sasaki, H. Kawai, T. Sato (Chuo U.), M. Shidatsu (Ehime U.), M. Oeda, K. Shiraishi (Tokyo Tech), S. Ueno, H. Tomida, M. Ishikawa, Y. Sugawara, N. Isobe, R. Shimomukai, M. Tominaga (JAXA), Y. Ueda, A. Tanimoto, S. Yamada, S. Ogawa, K. Setoguchi, T. Yoshitake (Kyoto U.), H. Tsunemi, T. Yoneyama, K. Asakura, S. Ide (Osaka U.), M. Yamauchi, S. Iwahori, Y. Kurihara, K. Kurogi, K. Miike (Miyazaki U.), T. Kawamuro (NAOJ), K. Yamaoka (Nagoya U.), Y. Kawakubo (LSU) report on behalf of the MAXI team: We examined MAXI/GSC all-sky X-ray images (2-20 keV) after the LVC trigger S190720a at 2019-07-20 00:08:36.747 UTC (GCN 25115). At the trigger time of S190720a, the high-voltage of MAXI/GSC was off, and it was turned on at T0+1076 sec (+17.9 min). The first one-orbit (92 min) scan observation with GSC after the event covered 90% of the 90% credible region of the bayestar skymap from 00:26:32 to 01:35:16 UTC (T0+1076 to T0+5200 sec). No significant new source was found in the region in the one-orbit scan observation. A typical 1-sigma averaged upper limit obtained in one scan observation is 20 mCrab at 2-20 keV. If you require information about X-ray flux by MAXI/GSC at specific coordinates, please contact the submitter of this circular by email.