TITLE: GCN CIRCULAR NUMBER: 20912 SUBJECT: GRB 170318A: Swift-BAT refined analysis DATE: 17/03/18 18:57:59 GMT FROM: Hans Krimm at NASA-GSFC/NSF J. R. Cummings (CPI),S. D. Barthelmy (GSFC), N. Gehrels (GSFC), H. A. Krimm (NSF/USRA),A. Y. Lien (GSFC/UMBC),C. B. Markwardt (GSFC), D. M. Palmer (LANL),T. Sakamoto (AGU),B. Sbarufatti (INAF-OAB/PSU), M. Stamatikos (OSU),T. N. Ukwatta (LANL)(i.e. the Swift-BAT team): Using the data set from T-239 to T+483 sec from the recent telemetry downlink, we report further analysis of BAT GRB 170318A (trigger #743065) (Sbarufatti, et al., GCN Circ. 20904). The BAT ground-calculated position is RA, Dec = 305.662, 28.408 deg which is RA(J2000) = 20h 22m 38.9s Dec(J2000) = +28d 24' 30.5" with an uncertainty of 1.2 arcmin, (radius, sys+stat, 90% containment). The partial coding was 43%. The mask-weighted light curve shows a single FRED-shaped pulse that starts approximately T+20 sec, peaks at T+2 sec and decays to background by T+100 sec. T90 (15-350 keV) is 133.7 +- 42.8 sec (estimated error including systematics). The time-averaged spectrum from -21.544 to 175.788 sec is best fit by a simple power-law model. The power law index of the time-averaged spectrum is 1.35 +- 0.11. The fluence in the 15-150 keV band is 3.7 +- 0.3 x 10^-06erg/cm2. The 1-sec peak photon flux measured from T+1.87 sec in the 15-150 keV band is 1.2 +- 0.3 ph/cm2/sec. All the quoted errors are at the 90% confidence level. The results of the batgrbproduct analysis are available at http://gcn.gsfc.nasa.gov/notices_s/743065/BA/