TITLE: GCN CIRCULAR NUMBER: 14240 SUBJECT: GRB 130216A: Further Swift-BAT refined analysis DATE: 13/02/18 14:57:39 GMT FROM: Takanori Sakamoto at AGU T. Sakamoto (AGU) and S. D. Barthelmy (GSFC) reports on behalf of the Swift-BAT team: Due to a issue in our automatic pipeline analysis script of the BAT data, we only reported the result based on a simple power-law fit at the spectral analysis section of the BAT refined circular (GCN Circ. 14229). However, this GRB had an enough signal-to-noise ratio in the spectrum to obtain Epeak by the BAT data alone. Therefore, we would like to update the spectral analysis part of the circular to: "The time-averaged spectrum from T-6.16 to T+4.31 sec is best fit by a power law with an exponential cutoff. This fit gives a photon index 0.80 +- 0.20, and Epeak of 123.7 +- 27.1 keV (chi squared 47.17 for 56 d.o.f.). For this model the total fluence in the 15-150 keV band is 3.0 +- 0.1 x 10^-06 erg/cm2 and the 1-sec peak flux measured from T+1.11 sec in the 15-150 keV band is 6.5 +- 0.3 ph/cm2/sec. A fit to a simple power law gives a photon index of 1.35 +- 0.04 (chi squared 72.98 for 57 d.o.f.). All the quoted errors are at the 90% confidence level. " We want to thank Alex Kann for pointing this out.