TITLE: GCN CIRCULAR NUMBER: 10685 SUBJECT: GRB 100425A: Swift-BAT refined analysis DATE: 10/04/25 13:38:39 GMT FROM: Scott Barthelmy at NASA/GSFC C. B. Markwardt (GSFC/UMD), S. D. Barthelmy (GSFC), W. H. Baumgartner (GSFC/UMBC), J. R. Cummings (GSFC/UMBC), N. Gehrels (GSFC), D. Grupe (PSU), H. A. Krimm (GSFC/USRA), D. M. Palmer (LANL), T. Sakamoto (GSFC/UMBC), M. Stamatikos (GSFC/ORAU), J. Tueller (GSFC), T. N. Ukwatta (GWU) (i.e. the Swift-BAT team): Using the data set from T-61 to T+242 sec from recent telemetry downlinks, we report further analysis of BAT GRB 100425A (trigger #420398) (Grupe, et al., GCN Circ. 10673). The BAT ground-calculated position is RA, Dec = 299.161, -26.463 deg, which is RA(J2000) = 19h 56m 38.7s Dec(J2000) = -26d 27' 47.8" with an uncertainty of 2.4 arcmin, (radius, sys+stat, 90% containment). The partial coding was 48%. The mask-weighted light curve shows three peaks. A first, precursor peak at ~T-45 sec, then the main peak at T-2 sec to ~T+10 sec, and the third peak at T+35 to ~T+65 sec. T90 (15-350 keV) is 37.0 +- 2.4 sec (estimated error including systematics). The time-averaged spectrum from T-2.1 to T+39.4 sec is best fit by a simple power-law model. The power law index of the time-averaged spectrum is 2.42 +- 0.32. The fluence in the 15-150 keV band is 4.7 +- 0.9 x 10^-7 erg/cm2. The 1-sec peak photon flux measured from T+0.27 sec in the 15-150 keV band is 1.4 +- 0.2 ph/cm2/sec. All the quoted errors are at the 90% confidence level. The results of the batgrbproduct analysis are available at http://gcn.gsfc.nasa.gov/notices_s/420398/BA/