batgrbproduct Analysis for Trigger=526270

Analysis Summary

Notes:

======================================================================
                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.46
    Process Start Time (local time): Thu Jul 12 16:29:07 EDT 2012
             Host Name: gcn5
   Current Working Dir: /local/data/raid16/prebascript_archive/trigger526270/batgroup_hand_proc
======================================================================

  Trigger: 00526270      Segment: 000

  BAT Trigger Time: 363669072   [s; MET]
      Trigger Stop: 363669136   [s; MET]
               UTC: 2012-07-11T03:11:02.587440    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 331.668154858708   Dec: 60.0195598602082  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    7.65
     Image Trigger?:     YES
     Rate S/N Ratio:     0  [ if not an image trigger ]
     Image S/N Ratio:    7.65

  Flight Position:   [ source = BAT ]
    RA: 331.668154858708   Dec: 60.0195598602082  [deg; J2000]


  Partial Coding Fraction:     [ including projection effects ]

 
  Angular difference between Flight and Ground position is 0.000000 arcmin
 
  Partial Coding Fraction:     [ including projection effects ]

  Duration
     T90: 0.0159999132156372 +/- 0.004
        Measured from: 95.5400000214577
                   to: 95.5559999346733     [s; relative to TRIGTIME]
     T50: 0.00799989700317383 +/- 0.004
        Measured from: 95.5440000295639
                   to: 95.5519999265671     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: 95.0519999861717     
                   to: 96.0519999861717     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: 95.5400000214577     
                   to: 95.5600000023842     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total    -0.001523  -0.002782  -0.002369  -0.002104
           0.000856   0.000948   0.000802   0.000888 [error]
 Peak     -0.004967  -0.004788  -0.010372  -0.011882
           0.006634   0.006217   0.006060   0.006090 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================
 
=== Fluence/Peak Flux Summary ===
 
              Model    Band1    Band2    Band3    Band4    Band5    Total      
                       15-25    25-50   50-100  100-350   15-150   15-350   keV
Fluence   Power-law 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00   erg/cm2
              Error 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00   erg/cm2
Peak flux Power-law 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00   ph/cm2/s
              Error 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00   ph/cm2/s
 
Fluence   Cutoff-PL 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00   erg/cm2
              Error 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00   erg/cm2
Peak flux Cutoff-PL 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00   ph/cm2/s
              Error 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00   ph/cm2/s
 
Fluence        Band 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00   erg/cm2
              Error 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00   erg/cm2
Peak flux      Band 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00   ph/cm2/s
              Error 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00 0.00e+00   ph/cm2/s
 
=== Time-averaged spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
 
=== 1-s peak spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
Model      : spectral model: simple power-law (PL) and cutoff power-law (CPL)
Ph_index   : photon index: E^-{Ph_index} (minus sign is not included in the index)
Ph_90err   : 90% error of the photon index
Epeak      : Epeak in keV
Epeak_90err: 90% error of Epeak
Norm       : normalization at 50 keV in PL model and at 1 keV in CPL model
Nomr_90err : 90% error of the normalization
chi2       : Chi-Squared
dof        : degree of freedom
 
=== T90/T50 calculation in the 50-300 keV band (BATSE band) using 64 ms lc ===
 
T90 in the 50-300 keV band: 0.000000 sec.
T50 in the 50-300 keV band: 0.000000 sec.
 
=== Table of the duration information ==
 
        Value   tstart    tstop
T100    0.020   95.540   95.560
T90     0.016   95.540   95.556
T50     0.008   95.544   95.552
Peak    1.000   95.052   96.052

Image

Pre-slew 15-350 keV image (Event data; bkg subtracted)

 
Foreground time interval of the image:
Background time interval of the image:

Lightcurves

Notes:

1 s binning

From T0-310 s to T0+310 s
From T100_start - 20 s to T100_end + 30 s
Full time interval

64 ms binning

Full time interval
From T100_start to T100_end
From T0-5 sec to T0+5 sec

16 ms binning

From T100_start-5 s to T100_start+5 s

8 ms binning

From T100_start-3 s to T100_start+3 s

2 ms binning

From T100_start-1 s to T100_start+1 s

SN=5 or 10 sec. binning (whichever binning is satisfied first)

SN=5 or 10 sec. binning (T < 200 sec)

Spectra

Notes:

Time averaged spectrum fit using the pre-slew DRM

Power-law model
Time interval is from   95.540 sec. to   95.560 sec.
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Cutoff power-law model
Time interval is from   95.540 sec. to   95.560 sec.
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file)            
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Band function
Time interval is from   95.540 sec. to   95.560 sec.
Usage: bat_spec_fit_band_sys.sh (pha file) (response file)      
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            

Peak spectrum fit

Power-law model
Time interval is from   95.052 sec. to   96.052 sec.
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Cutoff power-law model
Time interval is from   95.052 sec. to   96.052 sec.
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file)            
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Band function
Time interval is from   95.052 sec. to   96.052 sec.
Usage: bat_spec_fit_band_sys.sh (pha file) (response file)      
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Plot creation:
Thu Jul 12 16:42:48 EDT 2012