batgrbproduct analysis for trigger=1203197

batgrbproduct Analysis for Trigger=1203197

Analysis Summary

Notes:

======================================================================
                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time (local time): Wed Dec 20 09:54:34 EST 2023
             Host Name: batproc1
   Current Working Dir: /local/data/bat1/prebascript/trigger1203197/GCN5_download_cron
======================================================================

  Trigger: 01203197      Segment: 000

  BAT Trigger Time: 724697952   [s; MET]
      Trigger Stop: 724698280   [s; MET]
               UTC: 2023-12-19T16:58:39.423600    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 245.292501749288   Dec: -15.7981697429747  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    14.05
     Image Trigger?:     YES
     Rate S/N Ratio:     0  [ if not an image trigger ]
     Image S/N Ratio:    14.05

  Flight Position:   [ source = BAT ]
    RA: 245.292501749288   Dec: -15.7981697429747  [deg; J2000]

  Ground Position:   [ source = BAT pre-slew burst ]
    RA: 245.263509879892   Dec: -15.8117148687826  [deg; J2000]  
        { 16h 21m 03.2s , -15d 48' 42.2" }
         +/- 1.97321665966036 [arcmin] (estimated 90% radius based on SNR)
         +/- 1.05542339674674 [arcmin] (formal 1-sigma fit error)
    SNR: 11.5196724916608
 
  Angular difference between Flight and Ground position is 1.860626 arcmin
 
  Partial Coding Fraction: 0.2363281    [ including projection effects ]

  Duration
     T90: 51.3039999008179 +/- 13.5513021598204
        Measured from: 360.648000121117
                   to: 411.952000021935     [s; relative to TRIGTIME]
     T50: 20.4759999513626 +/- 13.2006287116797
        Measured from: 381.512000083923
                   to: 401.988000035286     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: 411.128000020981     
                   to: 412.128000020981     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: 359.047999978065     
                   to: 414.136000037193     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     2.058696   0.409396   0.045630  -0.003835
           0.122502   0.130830   0.115773   0.131817 [error]
 Peak      0.067235   0.037434   0.025246   0.034114
           0.018519   0.020157   0.018412   0.020794 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================
 
=== Fluence/Peak Flux Summary ===
 
              Model    Band1    Band2    Band3    Band4    Band5    Total      
                       15-25    25-50   50-100  100-350   15-150   15-350   keV
Fluence   Power-law 4.65e-06 7.25e-07 5.23e-08 4.02e-09 5.43e-06 5.43e-06   erg/cm2
              Error 4.49e-07 1.25e-07 2.25e-08 3.01e-09 4.53e-07 4.53e-07   erg/cm2
Peak flux Power-law 5.10e-01 4.64e-02 1.67e-03 6.24e-05 5.58e-01 5.58e-01   ph/cm2/s
              Error 5.11e-02 7.59e-03 7.03e-04 4.52e-05 5.06e-02 5.06e-02   ph/cm2/s
 
Fluence   Cutoff-PL 4.69e-06 5.18e-07 1.50e-09 1.11e-14 5.21e-06 5.21e-06   erg/cm2
              Error 4.80e-07 1.78e-07 1.29e-08 1.38e-10 4.92e-07 4.92e-07   erg/cm2
Peak flux Cutoff-PL 5.09e-01 3.51e-02 5.42e-05 2.11e-10 5.44e-01 5.44e-01   ph/cm2/s
              Error 5.51e-02 1.08e-02 4.31e-04 2.38e-06 5.50e-02 5.50e-02   ph/cm2/s
 
Fluence        Band -------- -------- -------- -------- -------- --------   erg/cm2
              Error -------- -------- -------- -------- -------- --------   erg/cm2
Peak flux      Band 4.64e-01 6.88e-03 2.23e-05 7.24e-08 4.71e-01 4.71e-01   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
=== Time-averaged spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
The chi2 of BB fit is 39.94 which shows a significant improvement in the fit over a PL.
Check the BB fit.
 
=== 1-s peak spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
Model      : spectral model: simple power-law (PL) and cutoff power-law (CPL)
Ph_index   : photon index: E^-{Ph_index} (minus sign is not included in the index)
Ph_90err   : 90% error of the photon index
Epeak      : Epeak in keV
Epeak_90err: 90% error of Epeak
Norm       : normalization at 50 keV in PL model and at 1 keV in CPL model
Nomr_90err : 90% error of the normalization
chi2       : Chi-Squared
dof        : degree of freedom
 
=== T90/T50 calculation in the 50-300 keV band (BATSE band) using 64 ms lc ===
 
T90 in the 50-300 keV band: 0.000000 sec.
T50 in the 50-300 keV band: 0.000000 sec.
 
=== Table of the duration information ==
 
        Value   tstart    tstop
T100   55.088  359.048  414.136
T90    51.304  360.648  411.952
T50    20.476  381.512  401.988
Peak    1.000  411.128  412.128

Image

Pre-slew 15-350 keV image (Event data; bkg subtracted)

#   RAcent  DECcent POSerr  Theta    Phi     Peak Cts     SNR  Name
  245.2635 -15.8117 0.0167   37.5  -67.8      14.1352    11.5  TRIG_01203197       
------------------------------------------
 
Foreground time interval of the image:
  0.000 168.690 (delta_t = 168.690 [sec])
170.000 177.170 (delta_t =   7.170 [sec])
179.000 276.430 (delta_t =  97.430 [sec])
278.000 288.600 (delta_t =  10.600 [sec])
290.000 297.680 (delta_t =   7.680 [sec])
299.000 328.000 (delta_t =  29.000 [sec])
Background time interval of the image:

Lightcurves

Notes:

1 s binning

From T0-310 s to T0+310 s
From T100_start - 20 s to T100_end + 30 s
Full time interval

64 ms binning

Full time interval
From T100_start to T100_end
From T0-5 sec to T0+5 sec

16 ms binning

From T100_start-5 s to T100_start+5 s

8 ms binning

From T100_start-3 s to T100_start+3 s

2 ms binning

From T100_start-1 s to T100_start+1 s

SN=5 or 10 sec. binning (whichever binning is satisfied first)

SN=5 or 10 sec. binning (T < 200 sec)

Spectra

Notes:

Time averaged spectrum fit using the pre-slew DRM

Power-law model
Time interval is from  359.048 sec. to  414.136 sec.
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Time interval is from  359.048 sec. to  414.136 sec.
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Time interval is from  359.048 sec. to  414.136 sec.
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            

Peak spectrum fit

Power-law model
Time interval is from  411.128 sec. to  412.128 sec.
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Time interval is from  411.128 sec. to  412.128 sec.
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Time interval is from  411.128 sec. to  412.128 sec.
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Plot creation:
Wed Dec 20 09:56:22 EST 2023