batgrbproduct analysis for trigger=1197507

batgrbproduct Analysis for Trigger=1197507

Analysis Summary

Notes:

======================================================================
                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time (local time): Tue Nov 21 03:58:08 EST 2023
             Host Name: batproc1
   Current Working Dir: /local/data/bat1/prebascript/trigger1197507/GCN5_download_cron
======================================================================

  Trigger: 01197507      Segment: 000

  BAT Trigger Time: 722132712   [s; MET]
      Trigger Stop: 722132776   [s; MET]
               UTC: 2023-11-20T00:24:39.599060    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 299.87026948837   Dec: 35.0640746037254  [deg; J2000]

     Catalogged Source?: YES
     Point Source?:      YES
     GRB Indicated?:     NO    [ by BAT flight software ]
     Image S/N Ratio:    17.79
     Image Trigger?:     YES
     Rate S/N Ratio:     0  [ if not an image trigger ]
     Image S/N Ratio:    17.79

  Flight Position:   [ source = BAT ]
    RA: 299.87026948837   Dec: 35.0640746037254  [deg; J2000]

  Ground Position:   [ source = BAT pre-slew burst ]
    RA: 299.825374591025   Dec: 35.0695650265056  [deg; J2000]  
        { 19h 59m 18.1s , +35d 04' 10.4" }
         +/- 1.27381175177284 [arcmin] (estimated 90% radius based on SNR)
         +/- 0.393106224290419 [arcmin] (formal 1-sigma fit error)
    SNR: 21.5262322228204
 
  Angular difference between Flight and Ground position is 2.229216 arcmin
 
  Partial Coding Fraction: 1    [ including projection effects ]

  Duration
     T90: 28.0119999647141 +/- 5.84216574372584
        Measured from: -88.5519999265671
                   to: -60.539999961853     [s; relative to TRIGTIME]
     T50: 13.8559999465942 +/- 8.5195773730765
        Measured from: -81.5119998455048
                   to: -67.6559998989105     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: -85.1679999828339     
                   to: -84.1679999828339     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: -89.7519999742508     
                   to: -59.4240000247955     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     0.326349   0.456211   0.213860  -0.023744
           0.051745   0.053521   0.045014   0.038163 [error]
 Peak      0.030667   0.035786   0.012240   0.003873
           0.010365   0.011400   0.009675   0.008307 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================
 
=== Fluence/Peak Flux Summary ===
 
              Model    Band1    Band2    Band3    Band4    Band5    Total      
                       15-25    25-50   50-100  100-350   15-150   15-350   keV
Fluence   Power-law 7.17e-07 1.02e-06 1.07e-06 2.08e-06 3.46e-06 4.89e-06   erg/cm2
              Error 4.96e-08 4.40e-08 7.19e-08 2.88e-07 1.66e-07 3.54e-07   erg/cm2
Peak flux Power-law 1.78e-01 2.11e-01 1.82e-01 2.66e-01 6.65e-01 8.36e-01   ph/cm2/s
              Error 8.29e-02 6.04e-02 4.90e-02 1.57e-01 1.64e-01 2.06e-01   ph/cm2/s
 
Fluence   Cutoff-PL 6.42e-07 1.10e-06 1.06e-06 6.55e-07 3.20e-06 3.45e-06   erg/cm2
              Error 5.96e-08 5.77e-08 8.15e-08 3.29e-07 1.97e-07 3.85e-07   erg/cm2
Peak flux Cutoff-PL 1.77e-01 2.11e-01 1.82e-01 2.64e-01 6.64e-01 8.34e-01   ph/cm2/s
              Error 1.32e-01 6.24e-02 5.56e-02 2.25e-01 1.67e-01 2.51e-01   ph/cm2/s
 
Fluence        Band 6.28e-07 1.10e-06 1.03e-06 1.13e-06 3.23e-06 3.91e-06   erg/cm2
              Error 6.09e-08 6.05e-08 8.70e-08 -------- 1.96e-07 --------   erg/cm2
Peak flux      Band -------- -------- -------- -------- -------- --------   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
=== Time-averaged spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
The chi2 of BB fit is 115.21 which shows a significant improvement in the fit over a PL.
Check the BB fit.
 
=== 1-s peak spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
Model      : spectral model: simple power-law (PL) and cutoff power-law (CPL)
Ph_index   : photon index: E^-{Ph_index} (minus sign is not included in the index)
Ph_90err   : 90% error of the photon index
Epeak      : Epeak in keV
Epeak_90err: 90% error of Epeak
Norm       : normalization at 50 keV in PL model and at 1 keV in CPL model
Nomr_90err : 90% error of the normalization
chi2       : Chi-Squared
dof        : degree of freedom
 
=== T90/T50 calculation in the 50-300 keV band (BATSE band) using 64 ms lc ===
 
T90 in the 50-300 keV band: 0.768000 sec.
T50 in the 50-300 keV band: 0.448000 sec.
 
=== Table of the duration information ==
 
        Value   tstart    tstop
T100   30.328  -89.752  -59.424
T90    28.012  -88.552  -60.540
T50    13.856  -81.512  -67.656
Peak    1.000  -85.168  -84.168

Image

Pre-slew 15-350 keV image (Event data; bkg subtracted)

#   RAcent  DECcent POSerr  Theta    Phi     Peak Cts     SNR  Name
  299.8254 +35.0696 0.0090    0.0 -147.6       4.7172    21.5  TRIG_01197507       
------------------------------------------
 
Foreground time interval of the image:
-13.000  -1.120 (delta_t =  11.880 [sec])
 -1.000  59.140 (delta_t =  60.140 [sec])
 61.000  61.928 (delta_t =   0.928 [sec])
 64.000  70.200 (delta_t =   6.200 [sec])
 72.000  75.900 (delta_t =   3.900 [sec])
 78.000  80.470 (delta_t =   2.470 [sec])
 83.000  86.400 (delta_t =   3.400 [sec])
 88.000  91.090 (delta_t =   3.090 [sec])
 94.000  96.810 (delta_t =   2.810 [sec])
 98.000  98.310 (delta_t =   0.310 [sec])
 99.000 100.036 (delta_t =   1.036 [sec])
Background time interval of the image:

Lightcurves

Notes:

1 s binning

From T0-310 s to T0+310 s
From T100_start - 20 s to T100_end + 30 s
Full time interval

64 ms binning

Full time interval
From T100_start to T100_end
From T0-5 sec to T0+5 sec

16 ms binning

From T100_start-5 s to T100_start+5 s

8 ms binning

From T100_start-3 s to T100_start+3 s

2 ms binning

From T100_start-1 s to T100_start+1 s

SN=5 or 10 sec. binning (whichever binning is satisfied first)

SN=5 or 10 sec. binning (T < 200 sec)

Spectra

Notes:

Time averaged spectrum fit using the pre-slew DRM

Power-law model
Multiple GTIs in the spectrum
tstart tstop
-89.752000 -61.770000
-61.000000 -60.400000
-60.000000 -59.424000
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Multiple GTIs in the spectrum
tstart tstop
-89.752000 -61.770000
-61.000000 -60.400000
-60.000000 -59.424000
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Multiple GTIs in the spectrum
tstart tstop
-89.752000 -61.770000
-61.000000 -60.400000
-60.000000 -59.424000
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            

Peak spectrum fit

Power-law model
Time interval is from  -85.168 sec. to  -84.168 sec.
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Time interval is from  -85.168 sec. to  -84.168 sec.
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Time interval is from  -85.168 sec. to  -84.168 sec.
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Plot creation:
Tue Nov 21 03:59:08 EST 2023