batgrbproduct analysis for trigger=1192737

batgrbproduct Analysis for Trigger=1192737

Analysis Summary

Notes:

======================================================================
                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time (local time): Wed Sep 27 12:42:41 EDT 2023
             Host Name: batproc1
   Current Working Dir: /local/data/bat1/prebascript/trigger1192737/GCN5_download_cron
======================================================================

  Trigger: 01192737      Segment: 000

  BAT Trigger Time: 717459144   [s; MET]
      Trigger Stop: 717459248   [s; MET]
               UTC: 2023-09-26T22:11:51.919180    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 83.7707708572143   Dec: 22.5020949358446  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    17.53
     Image Trigger?:     YES
     Rate S/N Ratio:     0  [ if not an image trigger ]
     Image S/N Ratio:    17.53

  Flight Position:   [ source = BAT ]
    RA: 83.7707708572143   Dec: 22.5020949358446  [deg; J2000]

  Ground Position:   [ source = BAT pre-slew burst ]
    RA: 83.770556616042   Dec: 22.4967315019795  [deg; J2000]  
        { 05h 35m 04.9s , +22d 29' 48.2" }
         +/- 1.31233201527931 [arcmin] (estimated 90% radius based on SNR)
         +/- 0.396908909180007 [arcmin] (formal 1-sigma fit error)
    SNR: 20.6292998632755
 
  Angular difference between Flight and Ground position is 0.322025 arcmin
 
  Partial Coding Fraction: 1    [ including projection effects ]

  Duration
     T90: 146.987999916077 +/- 80.7769325469858
        Measured from: 777.820000171661
                   to: 924.808000087738     [s; relative to TRIGTIME]
     T50: 75.2079999446869 +/- 59.9537401978635
        Measured from: 798.696000099182
                   to: 873.904000043869     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: 872.759999990463     
                   to: 873.759999990463     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: 775.151999950409     
                   to: 929.552000045776     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     1.779239   1.621147   0.745865   0.077330
           0.085335   0.086963   0.074470   0.065626 [error]
 Peak      0.046243   0.025934  -0.000935   0.003215
           0.007149   0.006218   0.005529   0.004986 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================
 
=== Fluence/Peak Flux Summary ===
 
              Model    Band1    Band2    Band3    Band4    Band5    Total      
                       15-25    25-50   50-100  100-350   15-150   15-350   keV
Fluence   Power-law 4.99e-07 6.24e-07 5.67e-07 8.97e-07 2.00e-06 2.59e-06   erg/cm2
              Error 4.24e-08 3.39e-08 5.64e-08 1.81e-07 1.25e-07 2.37e-07   erg/cm2
Peak flux Power-law 1.57e-01 1.09e-01 4.94e-02 3.12e-02 3.30e-01 3.46e-01   ph/cm2/s
              Error 1.36e-02 5.90e-03 4.72e-03 5.86e-03 1.85e-02 1.88e-02   ph/cm2/s
 
Fluence   Cutoff-PL 4.95e-07 6.29e-07 5.65e-07 7.77e-07 1.98e-06 2.47e-06   erg/cm2
              Error 4.68e-08 4.06e-08 5.83e-08 3.39e-07 1.47e-07 3.59e-07   erg/cm2
Peak flux Cutoff-PL 1.55e-01 1.09e-01 4.93e-02 2.79e-02 3.28e-01 3.42e-01   ph/cm2/s
              Error 1.53e-02 6.93e-03 4.81e-03 9.99e-03 2.00e-02 2.41e-02   ph/cm2/s
 
Fluence        Band -------- -------- -------- -------- -------- --------   erg/cm2
              Error -------- -------- -------- -------- -------- --------   erg/cm2
Peak flux      Band -------- -------- -------- -------- -------- --------   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
=== Time-averaged spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
The chi2 of BB fit is 128.74 which shows a significant improvement in the fit over a PL.
Check the BB fit.
 
=== 1-s peak spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
Model      : spectral model: simple power-law (PL) and cutoff power-law (CPL)
Ph_index   : photon index: E^-{Ph_index} (minus sign is not included in the index)
Ph_90err   : 90% error of the photon index
Epeak      : Epeak in keV
Epeak_90err: 90% error of Epeak
Norm       : normalization at 50 keV in PL model and at 1 keV in CPL model
Nomr_90err : 90% error of the normalization
chi2       : Chi-Squared
dof        : degree of freedom
 
=== T90/T50 calculation in the 50-300 keV band (BATSE band) using 64 ms lc ===
 
T90 in the 50-300 keV band: 0.000000 sec.
T50 in the 50-300 keV band: 0.000000 sec.
 
=== Table of the duration information ==
 
        Value   tstart    tstop
T100  154.400  775.152  929.552
T90   146.988  777.820  924.808
T50    75.208  798.696  873.904
Peak    1.000  872.760  873.760

Image

Pre-slew 15-350 keV image (Event data; bkg subtracted)

#   RAcent  DECcent POSerr  Theta    Phi     Peak Cts     SNR  Name
   83.7706 +22.4967 0.0094    0.3 -169.0       4.0514    20.6  TRIG_01192737       
------------------------------------------
 
Foreground time interval of the image:
  0.000 104.000 (delta_t = 104.000 [sec])
Background time interval of the image:

Lightcurves

Notes:

1 s binning

From T0-310 s to T0+310 s
From T100_start - 20 s to T100_end + 30 s
Full time interval

64 ms binning

Full time interval
From T100_start to T100_end
From T0-5 sec to T0+5 sec

16 ms binning

From T100_start-5 s to T100_start+5 s

8 ms binning

From T100_start-3 s to T100_start+3 s

2 ms binning

From T100_start-1 s to T100_start+1 s

SN=5 or 10 sec. binning (whichever binning is satisfied first)

SN=5 or 10 sec. binning (T < 200 sec)

Spectra

Notes:

Time averaged spectrum fit using the pre-slew DRM

Power-law model
Multiple GTIs in the spectrum
tstart tstop
775.152000 908.770000
910.000000 929.552000
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Multiple GTIs in the spectrum
tstart tstop
775.152000 908.770000
910.000000 929.552000
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Multiple GTIs in the spectrum
tstart tstop
775.152000 908.770000
910.000000 929.552000
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            

Peak spectrum fit

Power-law model
Time interval is from  872.760 sec. to  873.760 sec.
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Time interval is from  872.760 sec. to  873.760 sec.
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Time interval is from  872.760 sec. to  873.760 sec.
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Plot creation:
Wed Sep 27 12:44:28 EDT 2023