batgrbproduct analysis for trigger=1192251

batgrbproduct Analysis for Trigger=1192251

Analysis Summary

Notes:

======================================================================
                  BAT GRB EVENT DATA PROCESSING REPORT
    Process Script Ver: batgrbproduct v2.48
    Process Start Time (local time): Sun Sep 17 01:44:10 EDT 2023
             Host Name: batproc1
   Current Working Dir: /local/data/bat1/prebascript/trigger1192251/GCN5_download_cron
======================================================================

  Trigger: 01192251      Segment: 000

  BAT Trigger Time: 716530368   [s; MET]
      Trigger Stop: 716530432   [s; MET]
               UTC: 2023-09-16T04:12:15.982780    [includes UTCF correction] 
       Where From?: TDRSS position message

  BAT 
    RA: 261.77417118717   Dec: -17.0322347768231  [deg; J2000]

     Catalogged Source?: NO
     Point Source?:      YES
     GRB Indicated?:     YES    [ by BAT flight software ]
     Image S/N Ratio:    21.96
     Image Trigger?:     YES
     Rate S/N Ratio:     0  [ if not an image trigger ]
     Image S/N Ratio:    21.96

  Flight Position:   [ source = BAT ]
    RA: 261.77417118717   Dec: -17.0322347768231  [deg; J2000]

  Ground Position:   [ source = BAT pre-slew burst ]
    RA: 261.780115302483   Dec: -17.0323787082253  [deg; J2000]  
        { 17h 27m 07.2s , -17d 01' 56.6" }
         +/- 0.987986649103763 [arcmin] (estimated 90% radius based on SNR)
         +/- 0.251928032795693 [arcmin] (formal 1-sigma fit error)
    SNR: 30.9468780107376
 
  Angular difference between Flight and Ground position is 0.341114 arcmin
 
  Partial Coding Fraction: 0.6796875    [ including projection effects ]

  Duration
     T90: 7.19599997997284 +/- 7.72007696430923
        Measured from: 92.6960000991821
                   to: 99.892000079155     [s; relative to TRIGTIME]
     T50: 5.26399993896484 +/- 3.14233855948967
        Measured from: 93.4440001249313
                   to: 98.7080000638962     [s; relative to TRIGTIME]



  Fluence
     Peak Flux  (peak 1 second)
        Measured from: 95.7120000123978     
                   to: 96.7120000123978     [s; relative to TRIGTIME]
     Total Fluence        
        Measured from: 77.6799999475479     
                   to: 100.368000030518     [s; relative to TRIGTIME]
     
             Band 1     Band 2     Band 3     Band 4
              15-25      25-50     50-100    100-350     keV
 Total     0.407372   0.324972   0.084004  -0.016411
           0.028487   0.024836   0.019580   0.016692 [error]
 Peak      0.074828   0.053108   0.015342  -0.005307
           0.009970   0.008477   0.006811   0.005496 [error]

     [ fluence units of on-axis counts / fully illuminated detector ] 

======================================================================
 
=== Fluence/Peak Flux Summary ===
 
              Model    Band1    Band2    Band3    Band4    Band5    Total      
                       15-25    25-50   50-100  100-350   15-150   15-350   keV
Fluence   Power-law 1.28e-06 1.01e-06 5.44e-07 4.25e-07 3.03e-06 3.26e-06   erg/cm2
              Error 8.42e-08 4.60e-08 5.29e-08 7.99e-08 1.34e-07 1.60e-07   erg/cm2
Peak flux Power-law 6.62e-01 2.96e-01 7.92e-02 2.63e-02 1.05e+00 1.06e+00   ph/cm2/s
              Error 4.48e-02 1.31e-02 7.42e-03 4.64e-03 5.12e-02 5.06e-02   ph/cm2/s
 
Fluence   Cutoff-PL 1.18e-06 1.07e-06 4.72e-07 1.08e-07 2.81e-06 2.84e-06   erg/cm2
              Error 1.00e-07 5.81e-08 7.30e-08 9.17e-08 1.73e-07 2.04e-07   erg/cm2
Peak flux Cutoff-PL 6.09e-01 3.13e-01 7.06e-02 8.26e-03 9.99e-01 1.00e+00   ph/cm2/s
              Error 5.42e-02 1.65e-02 9.89e-03 -------- 5.93e-02 6.02e-02   ph/cm2/s
 
Fluence        Band -------- -------- -------- -------- -------- --------   erg/cm2
              Error -------- -------- -------- -------- -------- --------   erg/cm2
Peak flux      Band -------- -------- -------- -------- -------- --------   ph/cm2/s
              Error -------- -------- -------- -------- -------- --------   ph/cm2/s
 
=== Time-averaged spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
The chi2 of BB fit is 107.44 which shows a significant improvement in the fit over a PL.
Check the BB fit.
 
=== 1-s peak spectral analysis ===
 
Model Ph_index Ph_90err Epeak  Epeak_90err Norm     Nomr_90err chi2   dof
PL    0.000    0.000    -      -           0.00e+00 0.00e+00    0.000  0
CPL   0.000    0.000       0.0    0.0      0.00e+00 0.00e+00    0.000  0
 
Model      : spectral model: simple power-law (PL) and cutoff power-law (CPL)
Ph_index   : photon index: E^-{Ph_index} (minus sign is not included in the index)
Ph_90err   : 90% error of the photon index
Epeak      : Epeak in keV
Epeak_90err: 90% error of Epeak
Norm       : normalization at 50 keV in PL model and at 1 keV in CPL model
Nomr_90err : 90% error of the normalization
chi2       : Chi-Squared
dof        : degree of freedom
 
=== T90/T50 calculation in the 50-300 keV band (BATSE band) using 64 ms lc ===
 
T90 in the 50-300 keV band: 0.000000 sec.
T50 in the 50-300 keV band: 0.000000 sec.
 
=== Table of the duration information ==
 
        Value   tstart    tstop
T100   22.688   77.680  100.368
T90     7.196   92.696   99.892
T50     5.264   93.444   98.708
Peak    1.000   95.712   96.712

Image

Pre-slew 15-350 keV image (Event data; bkg subtracted)

#   RAcent  DECcent POSerr  Theta    Phi     Peak Cts     SNR  Name
  261.7801 -17.0324 0.0062   32.1    3.0       6.7522    30.9  TRIG_01192251       
------------------------------------------
 
Foreground time interval of the image:
  0.000  64.000 (delta_t =  64.000 [sec])
Background time interval of the image:

Lightcurves

Notes:

1 s binning

From T0-310 s to T0+310 s
From T100_start - 20 s to T100_end + 30 s
Full time interval

64 ms binning

Full time interval
From T100_start to T100_end
From T0-5 sec to T0+5 sec

16 ms binning

From T100_start-5 s to T100_start+5 s

8 ms binning

From T100_start-3 s to T100_start+3 s

2 ms binning

From T100_start-1 s to T100_start+1 s

SN=5 or 10 sec. binning (whichever binning is satisfied first)

SN=5 or 10 sec. binning (T < 200 sec)

Spectra

Notes:

Time averaged spectrum fit using the pre-slew DRM

Power-law model
Multiple GTIs in the spectrum
tstart tstop
77.680000 77.790000
92.000000 100.368000
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Multiple GTIs in the spectrum
tstart tstop
77.680000 77.790000
92.000000 100.368000
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Multiple GTIs in the spectrum
tstart tstop
77.680000 77.790000
92.000000 100.368000
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            

Peak spectrum fit

Power-law model
Time interval is from   95.712 sec. to   96.712 sec.
Usage: bat_spec_fit_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Cutoff power-law model
Time interval is from   95.712 sec. to   96.712 sec.
Usage: bat_spec_fit_cutoff_sys_xspec12.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Band function
Time interval is from   95.712 sec. to   96.712 sec.
Usage: bat_spec_fit_band_sys.sh (pha file) (response file) (script folder) (folder of taka's xspec lmodel)
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
script folder: /local/data/bat2/BATtools/battools/bin/GRB_spec_fit_v2
folder of taka's xspec lmodel: /local/data/bat1/prebascript/xspec_taka_lmodel
Single BB
Usage: bat_spec_fit_bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Thermal bremsstrahlung (OTTB)
Usage: bat_spec_fit_brems_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Double BB
Usage: bat_spec_fit_2bb_sys.sh (pha file) (response file)           
       This script tries to add the systematic column to the PHA
       file before doing the fitting                            
Plot creation:
Sun Sep 17 01:45:14 EDT 2023