TITLE: GCN CIRCULAR NUMBER: 9349 SUBJECT: GRB 090509, further Swift-BAT refined analysis DATE: 09/05/11 17:15:49 GMT FROM: Hans Krimm at NASA-GSFC H. A. Krimm (GSFC/USRA), S. D. Barthelmy (GSFC), and J. R. Cummings (GSFC/UMBC) for the Swift-BAT team. Here we report on further analysis of GRB 090509 (Grupe et al., GCN Circ. 9325) based on additional event data received since GCN Circ. 9335 (Tueller et al.) was issued. The results given here supersede those from GCN Circ. 9335. Using the data set from T-239 to T+316 sec from the recent telemetry downlink, we report further analysis of BAT GRB 090509 (trigger #351525). The BAT ground-calculated position is RA, Dec = 241.422, -28.385 deg which is RA(J2000) = 16h 05m 41.3s Dec(J2000) = -28d 23' 04.4" with an uncertainty of 2.1 arcmin, (radius, sys+stat, 90% containment). The partial coding was 29%. The mask weighted light curve consists of two sets of peaks widely separated in time. The first complex contains multiple overlapping peaks starting at ~T-4 sec, peaking at ~T+21 sec, and ending at ~T+40 sec. The second complex also contains multiple overlapping peaks starting at ~T+240 sec, peaking at ~T+250 sec and continuing until at least ~T+300 sec, when a pre-planned slew caused the source to move out of the BAT field of view. However until ~T+950 sec the source was at a location outside the field of view where high energy (> 50 keV) photons from the source could have penetrated the BAT shield and contributed to the non-maskweighted light curve. Examination of the raw light curve shows no additional peaks comparable in intensity to those described above. We cannot rule out weak source activity or activity below about 50 keV. Based on the available data, T90 (15-350 keV) is 335 +- 32 sec (estimated error including systematics). The time-averaged spectrum from T-62.6 to T+298.7 sec is best fit by a simple power-law model. The power law index of the time-averaged spectrum is 1.75 +- 0.20. The fluence in the 15-150 keV band is 3.3 +- 0.4 x 10-6 erg/cm2. The 1-sec peak photon flux measured from T+20.73 sec in the 15-150 keV band is 1.5 +- 0.3 ph/cm2/sec. All the quoted errors are at the 90% confidence level. The results of the batgrbproduct analysis are available at http://gcn.gsfc.nasa.gov/notices_s/351525/BA/